Impact Force Sensors

High-Speed Force Measurement for Impact & Transient Testing

Chunamur Labs provides impact force sensors and dynamic force measurement solutions for measuring short-duration, rapidly changing forces in impact and transient testing applications.

Impact force sensors are used where fast response, high stiffness, and high-frequency measurement are required to accurately capture force peaks and transient events. Piezoelectric/quartz force sensors are commonly used for these applications because of their high natural frequency and fast response.

chatgpt image sep 21, 2026, 10 02 42 pm

Impact Force Sensor Specifications

ModelForce CapacitySensitivityUpper FrequencyTemperature Range
208A1110 lb / 44.5 N500 mV/lb36 kHz−54 to +121°C
208A12100 lb / 445 N50 mV/lb36 kHz−54 to +121°C
208A13500 lb / 2.22 kN10 mV/lb36 kHz−54 to +121°C
208A141,000 lb / 4.45 kN5 mV/lb36 kHz−54 to +121°C
208A155,000 lb / 22.24 kN1 mV/lb36 kHz−54 to +121°C
208A242,500 lb / 11.12 kN1 mV/lb18 kHz−54 to +121°C
208A355,000 lb / 22.24 kN1 mV/lb20 kHz−54 to +121°C
208C0110 lb / 44.5 N500 mV/lb36 kHz−54 to +121°C
208C02100 lb / 445 N50 mV/lb36 kHz−54 to +121°C
208C03500 lb / 2.22 kN10 mV/lb36 kHz−54 to +121°C
208C041,000 lb / 4.45 kN5 mV/lb36 kHz−54 to +121°C
208C055,000 lb / 22.24 kN1 mV/lb36 kHz−54 to +121°C

Typical Applications

  • Impact and shock testing
  • Drop testing
  • Crash testing
  • Material impact testing
  • Stamping and punching
  • Crimping and forming
  • Product validation
  • Repetitive impact testing
  • Press-force measurement

Available Solutions

  • Piezoelectric / quartz force sensors
  • IEPE / ICP® force sensors
  • Dynamic force sensors
  • Impact force sensors
  • Force rings and load washers
  • High-frequency force sensors
  • Customized impact force measurement solutions

Impact sensors are available in different configurations and force ranges depending on the application. Dedicated impact sensors are used for applications such as drop, crash, shock, stamping, and repetitive impact testing.

How to Select an Impact Force Sensor

Selection depends on:

Peak Force | Impact Duration | Frequency Response | Natural Frequency | Accuracy | Overload | Mounting | Temperature | Output | DAQ Compatibility

The sensor’s natural frequency and rise time are particularly important when measuring very short impact pulses. The complete mechanical setup and mounting can also affect the dynamic response.

Application-Based Selection

Chunamur Labs helps select the right impact force sensor based on your technical requirements, application, and budget. Solutions can be evaluated from suitable manufacturers for both cost-sensitive industrial applications and demanding high-performance testing applications.

S

For general inquiries, please visit the Contact Us page

Scroll to Top