High-Speed Force Measurement for Impact & Transient Testing
Chunamur Labs provides impact force sensors and dynamic force measurement solutions for measuring short-duration, rapidly changing forces in impact and transient testing applications.
Impact force sensors are used where fast response, high stiffness, and high-frequency measurement are required to accurately capture force peaks and transient events. Piezoelectric/quartz force sensors are commonly used for these applications because of their high natural frequency and fast response.

Impact Force Sensor Specifications
| Model | Force Capacity | Sensitivity | Upper Frequency | Temperature Range |
|---|---|---|---|---|
| 208A11 | 10 lb / 44.5 N | 500 mV/lb | 36 kHz | −54 to +121°C |
| 208A12 | 100 lb / 445 N | 50 mV/lb | 36 kHz | −54 to +121°C |
| 208A13 | 500 lb / 2.22 kN | 10 mV/lb | 36 kHz | −54 to +121°C |
| 208A14 | 1,000 lb / 4.45 kN | 5 mV/lb | 36 kHz | −54 to +121°C |
| 208A15 | 5,000 lb / 22.24 kN | 1 mV/lb | 36 kHz | −54 to +121°C |
| 208A24 | 2,500 lb / 11.12 kN | 1 mV/lb | 18 kHz | −54 to +121°C |
| 208A35 | 5,000 lb / 22.24 kN | 1 mV/lb | 20 kHz | −54 to +121°C |
| 208C01 | 10 lb / 44.5 N | 500 mV/lb | 36 kHz | −54 to +121°C |
| 208C02 | 100 lb / 445 N | 50 mV/lb | 36 kHz | −54 to +121°C |
| 208C03 | 500 lb / 2.22 kN | 10 mV/lb | 36 kHz | −54 to +121°C |
| 208C04 | 1,000 lb / 4.45 kN | 5 mV/lb | 36 kHz | −54 to +121°C |
| 208C05 | 5,000 lb / 22.24 kN | 1 mV/lb | 36 kHz | −54 to +121°C |
Typical Applications
- Impact and shock testing
- Drop testing
- Crash testing
- Material impact testing
- Stamping and punching
- Crimping and forming
- Product validation
- Repetitive impact testing
- Press-force measurement
Available Solutions
- Piezoelectric / quartz force sensors
- IEPE / ICP® force sensors
- Dynamic force sensors
- Impact force sensors
- Force rings and load washers
- High-frequency force sensors
- Customized impact force measurement solutions
Impact sensors are available in different configurations and force ranges depending on the application. Dedicated impact sensors are used for applications such as drop, crash, shock, stamping, and repetitive impact testing.
How to Select an Impact Force Sensor
Selection depends on:
Peak Force | Impact Duration | Frequency Response | Natural Frequency | Accuracy | Overload | Mounting | Temperature | Output | DAQ Compatibility
The sensor’s natural frequency and rise time are particularly important when measuring very short impact pulses. The complete mechanical setup and mounting can also affect the dynamic response.
Application-Based Selection
Chunamur Labs helps select the right impact force sensor based on your technical requirements, application, and budget. Solutions can be evaluated from suitable manufacturers for both cost-sensitive industrial applications and demanding high-performance testing applications.