Reliable High-Force Compression Measurement
Chunamur Labs supplies high-capacity column compression-only load cells for reliable measurement of extremely high compressive forces in industrial, testing, calibration, and structural applications.
These load cells are designed for high-force measurement where robust construction, dependable performance, and accurate compression measurement are required. They are available in selected U.S. and metric configurations and can be specified according to the required capacity, dimensions, mounting arrangement, and application requirements.

Key Features
- Compression-only force measurement
- Capacity ranges from 300K to 1000K lbf
- Equivalent capacity range of approximately 1335 to 4450 kN
- Performance up to approximately ±0.15% FS
- Compact construction for high-capacity measurement
- U.S. and metric configurations
- Alloy-steel construction
- Multiple bridge options
- Standardized output option
- ASTM E74 calibration option
- Special thread sizes available
- Handle option available
- Suitable for high-force industrial and laboratory applications
Typical Specifications
| Parameter | Specification |
|---|---|
| Product Type | High-capacity column compression-only load cell |
| Measurement Type | Compression force |
| Available Capacity | 300K, 400K, 500K, and 1000K lbf |
| Equivalent Capacity | Approximately 1335 to 4450 kN |
| Performance | Up to approximately ±0.15% FS |
| Nonlinearity | ±0.15% FS |
| Hysteresis | ±0.10% FS |
| Nonrepeatability | ±0.10% RO |
| Creep, 20 minutes | ±0.05% |
| Rated Output | 2.0 mV/V nominal |
| Excitation Voltage | 10 VDC nominal; 15 V maximum |
| Bridge Resistance | 350 ohms nominal |
| Zero Balance | ±1.0% RO |
| Insulation Resistance | Greater than 5000 megohms |
| Safe Overload | 150% capacity |
| Construction | Alloy steel |
| Connector | MS3102A-14S-5P |
| Configuration | U.S. and metric models |
| Output | Standardized output option available |
| Calibration | ASTM E74 calibration option available |
Note: Exact capacity, accuracy, electrical characteristics, dimensions, thread size, and options depend on the selected model and must be confirmed from the applicable technical datasheet.
Typical Applications
High-capacity column compression-only load cells are commonly used for:
- High-force compression testing
- Structural testing systems
- Industrial weighing
- Hydraulic press force measurement
- Heavy-duty test benches
- Calibration and verification systems
- Material testing machines
- Component validation
- Load monitoring systems
- Research and development applications
Options
Depending on the selected model, the following options may be available:
- Multiple bridge configuration
- Standardized output
- ASTM E74 calibration
- Special thread size
- Handles
- U.S. or metric configuration
Accessories
- Mating connector
- Cable assembly
How to Select the Correct Model
The suitable load cell should be selected based on the complete mechanical and measurement requirements.
Consider the following parameters:
- Maximum compression force
- Normal operating load
- Required accuracy
- Overload requirement
- Static or dynamic loading condition
- Available installation space
- Loading surface dimensions
- Mounting and thread arrangement
- Load alignment
- Output and excitation requirements
- Calibration requirements
- Operating environment
- Indicator, PLC, or DAQ compatibility
The selected load cell should have sufficient capacity for the maximum expected load, including foreseeable overloads and transient forces. Avoid selecting a load cell only according to the normal operating load.
Integration
The load cell can be connected to suitable measurement and control equipment, including:
- Digital load indicators
- Weighing controllers
- Signal conditioners
- PLC systems
- Data acquisition systems
- Industrial computers
- Test and measurement software
Before connection, confirm the load cell’s rated output, excitation voltage, bridge resistance, connector arrangement, and signal-conditioning requirements.
Why Choose Chunamur Labs?
Chunamur Labs supports customers in identifying suitable high-capacity compression load cells based on their application and technical requirements.
Our support includes:
- Capacity selection
- Accuracy and performance evaluation
- Mechanical installation review
- Loading arrangement guidance
- Dimensional and thread verification
- Indicator and DAQ compatibility review
- Calibration requirement review
- Application-based product selection
- Technical coordination with the manufacturer
Looking for a High-Capacity Column Load Cell?
Looking for a compression-only load cell for high-force testing, structural measurement, industrial weighing, or calibration applications?
Please share your:
- Required capacity
- Accuracy requirement
- Installation dimensions
- Loading arrangement
- Output signal
- Operating conditions
- Calibration requirement
- Application details
Chunamur Labs will help you identify a suitable high-capacity column compression-only load cell for your application.